***MEDIA ADVISORY: EPA and ODEQ Officials to Honor Transformation of Collinsville, Okla., Superf

  ***MEDIA ADVISORY***   EPA and ODEQ Officials to Honor Transformation of Collinsville, Okla., Superfund Site into Habitat for Honeybees   (DALLAS – July 30, 2019) Tomorrow, U.S. Environmental Protection…

Continue Reading***MEDIA ADVISORY: EPA and ODEQ Officials to Honor Transformation of Collinsville, Okla., Superf

EPA Honors Houston Teacher and Students from Kingsville and Dallas, Texas, at Presidential Environm

EPA Honors Houston Teacher and Students from Kingsville and Dallas, Texas, at Presidential Environmental Youth Awards Ceremony   Media contacts: Jennah Durant or Joe Hubbard, [email protected] or 214 665-2200  …

Continue ReadingEPA Honors Houston Teacher and Students from Kingsville and Dallas, Texas, at Presidential Environm

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR 1.0 INCINERATOR, DIESEL, FIRED. Specifications Indicate if item offered complies with each specification.  1.1 General description      ▪      The incinerator should be a modern waste disposal unit, designed              to bum medical waste in a clean and environmentally efficient              manner. It should employ a temperature based logic control system              to provide optimum control of the operating conditions and              incorporate a high capacity thermal oxidizing secondary chamber.              It should be designed to retain the exhaust gases, for at least 2              seconds to ensure the unit's effective destruction of the combustion              products.      ▪      All the incinerators to be supplied and installed meet the              Waste Management Regulation 2006, legal notice No. 121 of              29th September 2006 and in particular 3rd schedule regulation              (26, 47) pertaining classification, standards, criteria, and              procedure for installing and operating incinerators.      ▪      The capacity of the incinerator required should be to the               specifications with a capacity to burn 100kgs/Hr.      ▪      The incinerator shall be run on a three-phase power supply               (mains).      ▪      For the technical evaluation, not only the treatment plant but               the entire system will be considered. It will be the responsibility               of the Bidder to supply a full system, including all eventually               additionally necessary secondary systems and additional               equipment.      ▪      The system offered shall be designed to operate normally under               the conditions of the purchaser's country. The conditions include …

Continue ReadingSPECIFICATIONS OF A DIESEL FIRED INCINERATOR

Fw: waste disposal range treatment capacity: 35 kg incinerator

  • Post author:
  • Post category:epost

 Suitable models for required waste disposal range.  Combustion efficiently per hour based on 08hrs operation and its fuel category  installation method C Mobile type/ possibility of structured inside container / structured in permanent base   Fuel consumption details consisting electricity  Capacity: 20KG/Hr, Temp Range: 600 Deg. C C 1100 Deg. C  Fuel Supply: Natural Gas/Diesel Dual Combustion Chamber Complete Scrubbing System (Dual  Resultant Gas Washer), Dual Blower, Chimney Height: 8m Electric Supply: 220/240Volt, Single Phase  Waste treatment capacity: 35 kg / h The combustion chamber is thick steel plate (3 to 10 mm ) with reinforcements, specially built . Front loading with watertight door mounted on hinges, locking screw wheel , flexible gasket and an insulating refractory lined  . An internal lining of refractory concrete containing 42% of H2 03 (alumina ) and 100 mm thick walls. fibrous insulation panels made ??of calcium silicate with a thickness of 75mm . Automatic Burner ( diesel or gas must be specified in the order ) with flames diving in one piece monoblock with an electronic  ignition system , permanent ventilation control valve and isolation valve. combustion floor made ??in carborundum , preventing binding of glass and slag. Equipped with two (02) chambers Fuel: Gas or butane gas Power supply: 220 V 50 Hz single-phase Capacity 100 Kg (0.18 m3) Electric starter ・       The room dimensions are 6.64 m width x 6.61 m length x 6.03 m height at lowest point/per one incinerator. Are these  dimensions sufficient for complete one medical incinerator 150 kg/hours (1.5ton/day). ・       Please, provide complete data about chemical consumption required for waste incineration, gas emission treatment  ,liquid waste and generated soiled wastes handling and/or, treatment . ・       Please, confirm that the exhaust gases are treated by alkaline scrubbing (wet or dry).

Continue ReadingFw: waste disposal range treatment capacity: 35 kg incinerator