TS50 Medical/General waste incinerator

Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: -  Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste  Waste density: 125 to 350Kg/M3  Waste CV: 4000 KCAL/kg  Moisture content: 10-25%  Estimated ash residue: 5-10%  Nominal capacity: 30Kg/hour batch load  Secondary chamber: 0.5 second @ 850oC Equipment  1No. Surefire TS50/1 Manual Load Incinerator comprising: -  Manual loading door  Horizontal solid hearth, refractory lined primary combustion chamber 800mm diameter x 2100mm long   Full sized bulk load/ash removal door  1 off diesel-fired ignition burner – temperature  controlled  1 off combustion air supply fan and distribution system, automatic control  High capacity secondary combustion chamber 0.5 second @>850oC  1 off diesel-fired afterburner – temperature controlled  Control panel – automatic operation  Temperature indication primary and secondary chambers 0-1200oC  Refractory lined flanged chimney to a height of 6M

Continue ReadingTS50 Medical/General waste incinerator

medical waste and general waste Incinerate

  • Post author:
  • Post category:epost

Incinerate: medical waste and general waste Capacity to burn waste: 400-500kg/hr Fuel: Diesel Fuel Consumption: 10 liters/hr maximum Incineration temperature: 950-1300 degrees centigrade Casing: thick (min 5mm) stainless steel casing and fully insulated to withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz Feeding: Automatic Ash/leftovers removal: Automatic Flue gas filtration system: Yes Quantity: Four (4)  Type: Pyrolytic  Use: For drugs  With Chassis to be Mounted in truck/lorry  May have a primary and secondary combustion chamber  Must have a dilution chamber Capacity: 100 Kgs per hour Power Source: Diesel or Natural Gas or Liquified Natural Gas 

Continue Readingmedical waste and general waste Incinerate

Incineration System for Medical Waste

Incineration System for Medical Waste (Capacity 6 Tons Per day); Incineration System for Medical Waste (Capacity 12 Tons Per day); Polluted air control technology i.e. ( Wet scrubber, bags); Flue gas treatment system (gas emission technology). What is the Gases Emission Standard you are using? What is the fuel you are using/recommending in your equipment? medical hospital incinerator Capacity: 30 Kg. destruction capacity: 3.000 kcal/kg diesel. max consume: 2.5 gal per hour. 1 camera: 1 burner capacity: 80.00 kcal Type: K (Ni-CrNi) enter size: 500x500mm ash door: 190 x 250mm 2 camera: 1 burner capacity: 80.000 kcal. Air conbustion: 0.5 HP Type: K (Ni-CrNi) Temperature 1 camera: Normal work temperature: 750 -900? C, Max temperature: 1000? C. 2 camera: Normal work temperature: 950-1000? C. Max temperature: 1100? C. Chimey: minimum 3 meters Controlator ciclo control 110-120 v / 60 Hz.

Continue ReadingIncineration System for Medical Waste