SPECIFICATIONS OF A DIESEL FIRED INCINERATOR

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR 1.0 INCINERATOR, DIESEL, FIRED. Specifications Indicate if item offered complies with each specification.  1.1 General description      ▪      The incinerator should be a modern waste disposal unit, designed              to bum medical waste in a clean and environmentally efficient              manner. It should employ a temperature based logic control system              to provide optimum control of the operating conditions and              incorporate a high capacity thermal oxidizing secondary chamber.              It should be designed to retain the exhaust gases, for at least 2              seconds to ensure the unit's effective destruction of the combustion              products.      ▪      All the incinerators to be supplied and installed meet the              Waste Management Regulation 2006, legal notice No. 121 of              29th September 2006 and in particular 3rd schedule regulation              (26, 47) pertaining classification, standards, criteria, and              procedure for installing and operating incinerators.      ▪      The capacity of the incinerator required should be to the               specifications with a capacity to burn 100kgs/Hr.      ▪      The incinerator shall be run on a three-phase power supply               (mains).      ▪      For the technical evaluation, not only the treatment plant but               the entire system will be considered. It will be the responsibility               of the Bidder to supply a full system, including all eventually               additionally necessary secondary systems and additional               equipment.      ▪      The system offered shall be designed to operate normally under               the conditions of the purchaser's country. The conditions include …

Continue ReadingSPECIFICATIONS OF A DIESEL FIRED INCINERATOR

Fw: waste disposal range treatment capacity: 35 kg incinerator

  • Post author:
  • Post category:epost

 Suitable models for required waste disposal range.  Combustion efficiently per hour based on 08hrs operation and its fuel category  installation method C Mobile type/ possibility of structured inside container / structured in permanent base   Fuel consumption details consisting electricity  Capacity: 20KG/Hr, Temp Range: 600 Deg. C C 1100 Deg. C  Fuel Supply: Natural Gas/Diesel Dual Combustion Chamber Complete Scrubbing System (Dual  Resultant Gas Washer), Dual Blower, Chimney Height: 8m Electric Supply: 220/240Volt, Single Phase  Waste treatment capacity: 35 kg / h The combustion chamber is thick steel plate (3 to 10 mm ) with reinforcements, specially built . Front loading with watertight door mounted on hinges, locking screw wheel , flexible gasket and an insulating refractory lined  . An internal lining of refractory concrete containing 42% of H2 03 (alumina ) and 100 mm thick walls. fibrous insulation panels made ??of calcium silicate with a thickness of 75mm . Automatic Burner ( diesel or gas must be specified in the order ) with flames diving in one piece monoblock with an electronic  ignition system , permanent ventilation control valve and isolation valve. combustion floor made ??in carborundum , preventing binding of glass and slag. Equipped with two (02) chambers Fuel: Gas or butane gas Power supply: 220 V 50 Hz single-phase Capacity 100 Kg (0.18 m3) Electric starter ・       The room dimensions are 6.64 m width x 6.61 m length x 6.03 m height at lowest point/per one incinerator. Are these  dimensions sufficient for complete one medical incinerator 150 kg/hours (1.5ton/day). ・       Please, provide complete data about chemical consumption required for waste incineration, gas emission treatment  ,liquid waste and generated soiled wastes handling and/or, treatment . ・       Please, confirm that the exhaust gases are treated by alkaline scrubbing (wet or dry).

Continue ReadingFw: waste disposal range treatment capacity: 35 kg incinerator

Solid waste incinerator placed in a container

  • Post author:
  • Post category:epost

Solid waste incinerator, productivity 100kg/h placed in a container.  Dimensions: 2,45x12,2m and 2,9m in height.   Operates natural gas with the pressure of 0.005 MPa and consumption of 0,21-0,23 m3 per kg of waste. Installed power C 55 kW. Total 3 units. Fuel capacity:200l or more Incinerator has a temperature monitoring system in place Wet scrubber capable of removing sulpur dioxide in the fumes Water capacity of 2000l or more Incinerator temeprature above 950 degree celsius Incinerator used a dual chamber system for incinerator Capacity per hour at least 25kg 1. A combustion chamber : a. watertight door for manual loading of waste. b . A burner start is limited to inflammation of waste . 2. A camera post-combustion gases : a. burner combustion , low power . b . An injection device air for total recombustion of the gases . c . An input device cooling air of the combustion gases. d . A smoke evacuation duct .   3. A control panel ensuring complete combustion cycle .   The incinerator meets as indicated on waste incineration . They will not burn plastics, packaging except that the amount so small that gases need not receive any treatment, secondary combustion chamber to 1100C handles everything ..   Water waste incinerator, productivity up to 3m3/h and placed in a modular building. Dimensions: 8,2x5,9m and 5m in height.  Operates natural gas with the pressure of 0,016 MPa and consumption of 0,35m3 / kg of drainage. Installed power C 35 kW. Total 1 unit.

Continue ReadingSolid waste incinerator placed in a container

Hot Medical Waste Disposing Machine

  • Post author:
  • Post category:epost

Type Pyrolytic:- Hot Medical Waste Disposing Machine Operation Condition 8-16 Hr /day Controls Built in data recording Incinerator  /Primary Combustion Chamber Type: continuous loading  Capacity/Burn rate per hour: 250 -300kg/hr  Temperature:  900-1200 oC   Material: External- 3 layers  Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shock Secondary  Combustion  Chamber Type: horizontal/vertical Temperature: 1200-1400 oC Residence time of gases : >2 seconds Material External- Low thermal mass insulation 14-30 oC  Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium nettle lining, resistant to corrosive waste or gas and to thermal shock. Ash Handling System Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash. Flue gas treatment   system        …

Continue ReadingHot Medical Waste Disposing Machine