diesel Fuel incinerators

  • Post author:
  • Post category:epost

diesel Fuel incinerators 16.  The supplier must provide necessary information for the best of the installation.  This incinerator with “PYROLYTIC”  combustion must have: 17.  A combustion chamber of waste:   Perfectly tight door for the manual loading of waste.  The loading should be manual, batch load.   A burner of lighting which the use is limited to the ignition of waste.   Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out  of refractory.   The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and  insulates bricks in order to assure a minimum temperature on the outside sheet metal.   Composition of the refractory;   Refractory concrete:     Thickness :>100mm     Nature: 42% of Al203   Insulate in fibrous panels:     Thickness: >75mm   Nature: Calcium silicate.   Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of  electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.   Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 18.  A chamber of post combustion of gases   A burner of combustion of gases,   A device of injection of air allowing a total re-combustion of gases,   A device of air inlet of cooling of waste gases,   A sheath of evacuation of the gases burnt,   Carcass in strong sheet steel with support of connection   Composition of the refractory;   Refractory concrete:…

Continue Readingdiesel Fuel incinerators

HIGH TECH PYROLYTIC MEDICAL WEST INCINERATOR

 HIGH TECH PYROLYTIC MEDICAL WEST INCINERATOR 1.Capacity of destruction in weight: 60Kg/h 2.It should be able to operate not less than 10 hours/day. 3.This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics,  laboratories, institutes, etc.. 4.Design Specification: Types A, B, C, D and E of medical waste 5."PYROLYTIC" combustion by controlling the gasification of waste. 6.The incinerator must avoid the release of black smoke and fine dust, (smokeless) during the loadings. 7.It should be able to reduce the volume of wastes by 98% 8.It should be able to hold emission in the second burn with gas residence of not less than 2 seconds. 9.The incineration should be completely free from visible smoke as well as offensive odours. 10.  The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg   the temperatures of combustion: Minimum will be 850oC and max 1400oC   post combustion:>1100oC 11.  The internal diameter of the chimney:Ø400 and its height: 8m 12.  The volume of the combustion chamber: 1,200L 13.  The dimension of the door for loading in cm: 70 x 70 14.  Burner operation should be automatic on/off

Continue ReadingHIGH TECH PYROLYTIC MEDICAL WEST INCINERATOR

Hot Medical Waste Disposing Machine Burn rate per hour: 250 -300kg/hr

  • Post author:
  • Post category:epost

Incinerator should be smokeless, odourless combustion and it should be made by high-quality cast, insulation, and steel plate as well as minimum generation of dust. Moreover the incinerator should be corrosion resistant.    Type Pyrolytic:- Hot Medical Waste Disposing Machine   Operation Condition 8-16 Hr /day Controls Built in data recording Incinerator /Primary Combustion Chamber Type: continuous loading Capacity/Burn rate per…

Continue ReadingHot Medical Waste Disposing Machine Burn rate per hour: 250 -300kg/hr

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR

  • Post author:
  • Post category:epost

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR Incinerator type: Animal waste incinerator Load Capacity minimum:  1500 kg Burner fuel type:  Diesel Burner fuel rate max.:   20-25 Liter diesel/ per hour Burners minimum: 3 Burning rate minimum: 200-300kg/per hour Furnace bar area minimum: 2 м3 Fuel tank capacity minimum: 300L Main chamber burning temperature min. 1100 0C Afterburner chamber burning temperature min.  1300 0C Power supply 220V Incinerator items and electrical appliances should be weather proof and humidity resistant within the range of 30-90 % Incinerator should be compliant to the environmental protection rules in accordance to national legislation Maximum dimensions C Length C 5m, width C 3.5m, height C 5m INCINERATOR, DIESEL, FIRED. Specifications Indicate if item offered complies with each specification.  1.1 General description   The incinerator should be a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner. It should employ a temperature based logic control system to provide optimum control of the operating conditions and incorporate a high capacity thermal oxidizing secondary chamber. It should be designed to retain the exhaust gases, for at least 2 seconds to ensure the unit's effective destruction of the combustion products.   For the Supply, installation & commissioning of a Medical Waste Incinerator as detailed below: i. Waste type Health care waste   ii. Waste density…

Continue ReadingSPECIFICATIONS OF A DIESEL FIRED INCINERATOR

Incinerator smokeless and odourless combustion-hot medical waste disposing machine

  • Post author:
  • Post category:epost

Incinerator should be smokeless, odourless combustion and it should be made by high-quality cast, insulation, and steel plate as well as minimum generation of dust. Moreover the incinerator should be corrosion resistant.  Type of incinerator : Pyrolitic – hot medical waste disposing machine Operation Condition: 8-16 hr/ day  Control: Built-in data recording Operating temperature: Incinerator  /Primary Combustion Chamber Primary Chamber: 900 – 1200 0C Type: continuous loading, Top Loading Capacity/Burn rate per hour: 250 -300 kg/hr  Material: External- 3 layers  Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shock Secondary  Combustion  Chamber: Type: horizontal/vertical Temperature:  1200- 1300 oC Residence time of gases : >2 seconds Ash Residue: <5% of original waste size Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc  Auxiliary device: Fuel cut-off device Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                       Chimney (Stack): Type: Vertical type height:>7 meter’ Material: Fireproof cast, stainless steel OUTPUT:  GAS- SMOKELESS,ODORLESS …

Continue ReadingIncinerator smokeless and odourless combustion-hot medical waste disposing machine