Medical waste incinerators bio Capacity incinerator medical waste to high combustion temperature

  • Post author:
  • Post category:epost

Medical waste incinerator bio Capacity incinerator medical waste to high combustion temperature  With a smokeless device to protect the environment and with two combustion chambers equipped with gas burners or oil  -incinerator to burn large volume pieces of 70 cm  deviation: Automatic Control System  -destructive capacity from 20 to 30 kgs  First-room / Temperature = 900 ° C combustion  2nd bedroom / Temperature = 1200 ° c afterburner  -burner = 116Kw Burning Rate: 50Kg/Hr Feed Capacity: 150Kgs  Primary Combustion Chamber: 900 Litres Secondary Combustion Chamber: 300 Litres Mix Combustion Chamber: Yes Smoke Filter Chamber: Yes Feed Mode: Manual Power: 0.7kW Fuel Type: Diesel/LPG/Natural Gas Internal Dimension: 120 x 90 x 85cm (Primary Chamber) External Dimensions: 200 x 160 x 310cm (Without Chimney) Burning Efficiency: >98%

Continue ReadingMedical waste incinerators bio Capacity incinerator medical waste to high combustion temperature

Design standard Multiple chamber incinerator

  • Post author:
  • Post category:epost

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse  Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length  Width  Height  Extra width for burners…

Continue ReadingDesign standard Multiple chamber incinerator

diesel Fuel incinerators

  • Post author:
  • Post category:epost

diesel Fuel incinerators 16.  The supplier must provide necessary information for the best of the installation.  This incinerator with “PYROLYTIC”  combustion must have: 17.  A combustion chamber of waste:   Perfectly tight door for the manual loading of waste.  The loading should be manual, batch load.   A burner of lighting which the use is limited to the ignition of waste.   Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out  of refractory.   The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and  insulates bricks in order to assure a minimum temperature on the outside sheet metal.   Composition of the refractory;   Refractory concrete:     Thickness :>100mm     Nature: 42% of Al203   Insulate in fibrous panels:     Thickness: >75mm   Nature: Calcium silicate.   Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of  electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.   Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 18.  A chamber of post combustion of gases   A burner of combustion of gases,   A device of injection of air allowing a total re-combustion of gases,   A device of air inlet of cooling of waste gases,   A sheath of evacuation of the gases burnt,   Carcass in strong sheet steel with support of connection   Composition of the refractory;   Refractory concrete:…

Continue Readingdiesel Fuel incinerators

HIGH TECH PYROLYTIC MEDICAL WEST INCINERATOR

 HIGH TECH PYROLYTIC MEDICAL WEST INCINERATOR 1.Capacity of destruction in weight: 60Kg/h 2.It should be able to operate not less than 10 hours/day. 3.This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics,  laboratories, institutes, etc.. 4.Design Specification: Types A, B, C, D and E of medical waste 5."PYROLYTIC" combustion by controlling the gasification of waste. 6.The incinerator must avoid the release of black smoke and fine dust, (smokeless) during the loadings. 7.It should be able to reduce the volume of wastes by 98% 8.It should be able to hold emission in the second burn with gas residence of not less than 2 seconds. 9.The incineration should be completely free from visible smoke as well as offensive odours. 10.  The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg   the temperatures of combustion: Minimum will be 850oC and max 1400oC   post combustion:>1100oC 11.  The internal diameter of the chimney:Ø400 and its height: 8m 12.  The volume of the combustion chamber: 1,200L 13.  The dimension of the door for loading in cm: 70 x 70 14.  Burner operation should be automatic on/off

Continue ReadingHIGH TECH PYROLYTIC MEDICAL WEST INCINERATOR