Incinerator Requirements

  • Post author:
  • Post category:epost

The requirements for a unit are as follows: 1. chemical agents to be utilized: • 10% heptyl (unsymmetrical dimethylhydrazine) water solution, • heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m³ concentration, • 10% azotic (nitric) acid water solution, • azotic (nitric) acid vapour with concentration up to 1.1 kg/m³; 2. neutralization method: thermal decomposition; 3. neutralization temperature: +800˚C to +1200˚C; 4. performance: • vapour capacity: 70 to 200 m³/h, • water solution capacity: 50 to 500 l/h; 5. inlet pressure: up to 2 bars; 6. automatic control system; 7. overall dimensions shall allow for mounting the unit on a vehicle chassis. We have viewed through your product range and, perhaps, YD15C- YD30model or YD50- YD500 model will suit our application best. If so, please confirm this. If not, what model, in your opinion, can meet our requirements better? 

Continue ReadingIncinerator Requirements

Incinerator Requirements

The requirements for a unit are as follows: 1. chemical agents to be utilized: • 10% heptyl (unsymmetrical dimethylhydrazine) water solution, • heptyl (unsymmetrical dimethylhydrazine) vapour with 0.8 to 1.0 kg/m³ concentration, • 10% azotic (nitric) acid water solution, • azotic (nitric) acid vapour with concentration up to 1.1 kg/m³; 2. neutralization method: thermal decomposition; 3. neutralization temperature: +800˚C to +1200˚C; 4. performance: • vapour capacity: 70 to 200 m³/h, • water solution capacity: 50 to 500 l/h; 5. inlet pressure: up to 2 bars; 6. automatic control system; 7. overall dimensions shall allow for mounting the unit on a vehicle chassis. We have viewed through your product range and, perhaps, YD15C- YD30model or YD50- YD500 model will suit our application best. If so, please confirm this. If not, what model, in your opinion, can meet our requirements better? 

Continue ReadingIncinerator Requirements

TECHNICAL SPECIFICATIONS FOR NAMAPA HOSPITAL,INCINERATOR 20KG

  • Post author:
  • Post category:epost

INCINERATOR 20KG General Specifications 6mm plate steel sheel construction 11cm 1400 º C Refractory L iner Temperature controlled Burners Secondary combustion Burners Interlock Switch on Load Doors Separate Ash Door One Second secondary Residence @ 1000 º C 400 ° C Silicone Based Paint Finish. Alloy Temperature Sensor Factory wired and tested Capacity-20 kg / hr Primary Chamber-1607 L Hearth Area-1:36 sq. m Secondary Chamber-694 L Primary Burner (oil)-420,000 btu Secondary Burner (oil)-900,000 btu secondary Combustion-1/6 hp Exhaust Stack-46cm x 6m Electrical Service-220/50 Weight System-5.700 kg Dimension "D"-152cm Load Port Height- 60x 60 cm Ash Port Height -36 x 36 cm Electrically operated incinerator In a simple design with a metal steel drum electric. including:  A cage for receipt of biomedical waste;  A combustion chamber with fireplace with a filter to retain ashes;  A cover;…

Continue ReadingTECHNICAL SPECIFICATIONS FOR NAMAPA HOSPITAL,INCINERATOR 20KG