SPECIFICATIONS OF THE MEDICAL BIOLOGICAL WASTE INCINERATOR

  • Post author:
  • Post category:epost

SPECIFICATIONS OF THE MEDICAL/BIOLOGICAL WASTE  INCINERATOR It should  be  a three chambered incinerator  The load capacity of 250 kg The housing for the incinerator should be able to withstand the temperatures and other operational requirements. The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200oc. It should have a strong base for the machine to keep it stable, firm and secure during its operational lifespan. The primary (combustion) and the secondary (scorching) chambers to be fitted with burners for effective combustion. In the third chamber, scrubbers and precipitators will need to be installed as pollution control equipment before emission of gases into the atmosphere. A system for continuous emission Monitoring and Environmental Monitoring. A mechanism with which to treat the waste water before discharge into the sewerage system. Temperature control and monitoring devices (probe thermometer) should be availed to ensure that the right temperatures are attained in the chambers during operation. Motor (fans) sufficient to induce enough air into the combustion chambers and direct the gases towards the flue 9 chimney). High power electricity and emergency generator connection for automated ignition purposes. The chimney should be tall enough and be at least one meter above the tallest building in the vicinity. The fuel tank (industrial diesel) to be constructed next to but out side the incinerator housing for security purposes and to prevent fire hazards. Capacity of 250. Other Requirements Training of all the personnel involved in health care waste (HCW) management. The Automatic Feeding system of the Incinerator Automatic waste loading mechanism with conveyor belts. These will lead the waste into the first primary chamber. An Automatic bottom ashes discharge system.

Continue ReadingSPECIFICATIONS OF THE MEDICAL BIOLOGICAL WASTE INCINERATOR

Incinerator Spare part list

Spare part list - Ignition burner                          Item description                   N0 of required                             Motor                                       2                          Control box                              2                           Pump couplings                       4                          Photo cells                               2                          Sets ht. leads                           2                          Sets electrodes                         4                          Oil valve                                   1                          Nozzle                                       2                                                             Spare part list - After burners                          Item description                   N0 of required                             Motor                                       2                          Control box                              2                           Pump couplings                       4                          Photo cells                               2                          Sets ht. leads                           2                          Sets electrodes                         4                          Oil valve                                   1                          Nozzle                                       2 Spare part list – Ram loader                           Item description                   N0 of required                         Reed switch                               4                        Seal kit                                       1      Medical waste incinerator Accessories  - Clean out tools - Loading and ash removal methods.      - Fuel storage tank with the two pump and all accessories.  - Flue gas cleaning system…

Continue ReadingIncinerator Spare part list

MEDICAL/BIOLOGICAL WASTE INCINERATOR

  • Post author:
  • Post category:epost

SPECIFICATIONS OF THE MEDICAL/BIOLOGICAL WASTE  INCINERATOR It should  be  a three chambered incinerator  The load capacity of 250 kg The housing for the incinerator should be able to withstand the temperatures and other operational requirements. The chimney should have a strong refractory lining of special type of cement to withstand temperatures more than 1200oc. It should have a strong base for the machine to keep it stable, firm and secure during its operational lifespan. The primary (combustion) and the secondary (scorching) chambers to be fitted with burners for effective combustion. In the third chamber, scrubbers and precipitators will need to be installed as pollution control equipment before emission of gases into the  atmosphere. A system for continuous emission Monitoring and Environmental Monitoring. A mechanism with which to treat the waste water before discharge into the sewerage system. Temperature control and monitoring devices (probe thermometer) should be availed to ensure that the right temperatures are attained in the  chambers during operation. Motor (fans) sufficient to induce enough air into the combustion chambers and direct the gases towards the flue 9 chimney). High power electricity and emergency generator connection for automated ignition purposes. The chimney should be tall enough and be at least one meter above the tallest building in the vicinity. The fuel tank (industrial diesel) to be constructed next to but out side the incinerator housing for security purposes and to prevent fire  hazards. Capacity of 250. Other Requirements Training of all the personnel involved in health care waste (HCW) management. The Automatic Feeding system of the Incinerator Automatic waste loading mechanism with conveyor belts. These will lead the waste into the first primary chamber. An Automatic bottom ashes discharge system.

Continue ReadingMEDICAL/BIOLOGICAL WASTE INCINERATOR

Spesifikasi Incinerator 200kg/jam

Spesifikasi Incinerator 200kg/jam Spesifikasi dan Daftar Material Dimensi dan Power Capacity Nama Barang                                : INCINERATOR Type / Model                 : PWR-INC-KMN 20 Kapasitas                                 : 200kg/Jam (2 m3) Length                               : 384 cm   Width                                : 182 cm   Height                                    : 213 cm   Height of Chimney std            : 700 cm   TOTAL WEIGHT                   : 9.500 kg  Panel – timer                 : Digital Included Auto Alarm Finishing                            : Hot endured paint  Fuel tank                           : 200 Liter  Covering Element from steel   : 3-8mm  Banyaknya Burner                   : 3 pcs   Banyaknya Blower               : 2 pcs  Max. Fuel consumption           : 15-40 Liter/Jam  Max. Elektric consumption …

Continue ReadingSpesifikasi Incinerator 200kg/jam

complete with electric ignition and flame failure controls wired with continuous running fan

The waste will be reduced by 90~95% to leave 10 -5% ash   2.4 Quality/Environmental Standards   NEMA ACT (EMCA) 1999 BS3316   2.5 Operating Period   Anticipated daily operating period 8 hours   Maximum operating period 12 hours   2.6 Chamber   Should be refractory lined to the following standard; Hearth and lower section of chamber walls   2.7 Hot face material   Super duty firebrick   Limiting continuous service limit 1500°C   Thickness 100mm   Thermal conductivity 1.3 W/mk  …

Continue Readingcomplete with electric ignition and flame failure controls wired with continuous running fan

a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner

  • Post author:
  • Post category:epost

The incinerator should be a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner. It  should employ a temperature based logic control system to provide optimum control of the operating conditions and incorporate a high capacity  thermal oxidizing secondary chamber. It should be designed to retain the exhaust gases, for at least 2 seconds to ensure the unit's effective  destruction of the combustion products.   i. Waste type Health care waste   ii. Waste density 125 to 350Kg/M3   iii.. Waste Calorific Value 4000 KCAL/Kg   iv. Moisture content 10-25%   v.  Estimated ash  residue 5-10%   vi.  Nominal capacity  50Kg/hour batch load   vii.…

Continue Readinga modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner