incinerator manufacturers
GOODS: ONE INCINERATORS IN ACCORDANCE WITH THE SUPPLIER’ REQUIREMENT S OWN PROPOSED …
GOODS: ONE INCINERATORS IN ACCORDANCE WITH THE SUPPLIER’ REQUIREMENT S OWN PROPOSED …
Primary chamber: Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature sensor points with complete internal fans. Secondary Chamber: Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times. Third Chamber: Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time. Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters. Chimney: Heavy duty 5mm or more stainless steel casing mild steel casing. Stack cap/spark arrestors. Control Panel: a.Temperature Monitoring with 4 digit display. b.Thermostat control device for burner (fuel saver) c.Temperature control 0-12 hours. d.Integral fan timer control
Model A1500 (customer made design) Interior Measurements 150 x 100 x 96cm Suitable For Family Pet Feline – – – – yes – Pet pet dog – yes – Pig…
(G) Technical Specifications of Spore tester Features and Specifications : It is an auto reader for Bacillus Stearothermophilus to test the spore discharge after treatment (sterilization) of the waste. should…
Key Product Checklist Main Burning Chamber Additional Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Circumstance Smokeshaft:5.0 Meters *( upgrade to Stainless Steel, cost-free cost) Italy oil burner: 02…
We finish this project in year 2010 to 2011 and also distribution to Hochiminh port, Vietnam with 1×× 40′ feet open leading full container. Items/Model YD-500 Burning Rate (kgs/Hour) 500…
TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals INTRODUCTION All the incinerators to be supplied and installed must meet the Government of Kenya waste Management Regulation 2006 in particular 3rdschedule regulation…
There are 03 sets Design YD-100 circulation to Iraq between year 2013 to 2014. The heater use for neighborhood a number of structure as well as construction sites in addition…
Documents to be submitted as following ; Fabricators accreditations Test report to prove ZERO harmful emission level provided as samples form other installations Test report to prove sterility achieved at…
Heater Layout YD-30 for Australia Melbourne client. Items/Model YD-30 Burning Rate (kgs/Hour). 30 kgs/Hr. Feed Ability (kgs). 60 kgs. Tools Weight. 2300 kgs. Main Chamber (Liters). 360. 2nd Chamber (Liters).…