Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container,  supplied with the following specifications: complete with constant ventilation fans for extraction,  factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping.  Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner  b. Dedicated independent fan system, damper controlled.  c. Thermostatic Sensor  d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner b. Thermostatic Sensor  c. Minimum Temperature of 1100 deg.C as per WHO guidelines.  d. Two second retention time – Proven with CFD modeling. Steel Construction: a. constructed from 8mm & 1Omm steer plate …

Continue ReadingMobile Diesel Fired Incinerator in container

Medical Incinerator Specification

Capacity Not less than 500Kg/hr. Operation 24hr-7days/week continuous operation. Combustion chamber 2 combustion chamber. Temp. First combustion chamber 800-1000 C. Secandry combustion chamber 1000-1200 C, with the possibility to be upgraded to 1400 C. Combustion Efficiency 99.99% Retention time Of the flow gases not less than 2 Sec in the hot portion. Excess Oxygen concentration Of primary combustion chamber 3-6% max. Refractory The chambers should be lined with high thermal insulating refractory bricks with suitable thickness and with highly temp.  resistance. Not less than 1400 C for the first combustion chamber, and not less than 1600 C for the secandry combustion chamber, and at the  same time prevent the Temp. of the outside body of the chamber not higher than 70 C. Doors Should be lined with the same bricks, and the edges lined with special suitable insulating material to prevent any gas escaping, and  the doors should be kept under negative pressure during the operation. Air Emission Control System With high destruction and removal efficiency (DRE). Not less than 99.9999 as per KEPA. Wet System If the system equiped with a CEMS washing the flow gas with water, then it should be manufactured from suitable anti  corrossion materials, and equiped with pH meter to measure and neutralize the water. It should be able to use the water in closed recycled  circuit many times before treating/ discharging into the sewage system in compliance with KEPARS. Chemical dosing It should be equiped with suitable autochemical dosing system to control the pH for the water of the wet scrubber system …

Continue ReadingMedical Incinerator Specification

Medical Incinerator Specification

Capacity Not less than 500Kg/hr. Operation 24hr-7days/week continuous operation. Combustion chamber 2 combustion chamber. Temp. First combustion chamber 800-1000 C. Secandry combustion chamber 1000-1200 C, with the possibility to be upgraded to 1400 C. Combustion Efficiency 99.99% Retention time Of the flow gases not less than 2 Sec in the hot portion. Excess Oxygen concentration Of primary combustion chamber 3-6% max. Refractory The chambers should be lined with high thermal insulating refractory bricks with suitable thickness and with highly temp.  resistance. Not less than 1400 C for the first combustion chamber, and not less than 1600 C for the secandry combustion chamber, and at the  same time prevent the Temp. of the outside body of the chamber not higher than 70 C. Doors Should be lined with the same bricks, and the edges lined with special suitable insulating material to prevent any gas escaping, and  the doors should be kept under negative pressure during the operation. Air Emission Control System With high destruction and removal efficiency (DRE). Not less than 99.9999 as per KEPA. Wet System If the system equiped with a CEMS washing the flow gas with water, then it should be manufactured from suitable anti  corrossion materials, and equiped with pH meter to measure and neutralize the water. It should be able to use the water in closed recycled  circuit many times before treating/ discharging into the sewage system in compliance with KEPARS. Chemical dosing It should be equiped with suitable autochemical dosing system to control the pH for the water of the wet scrubber system …

Continue ReadingMedical Incinerator Specification

Supply of Inclinators for Interim Arrival Domestic Terminal Project

CMC Services for Inclinators for 3 years including all spares, consumables, Skilled Manpower, tools and tackles all complete. As per Scope attached as Annexure Design, Manufacture, Supply, delivery to site, installation, testing & commission of All weather proof Passenger Inclinators in accordance to the Scope and outline specifications mentioned in AnnexureSpesifikasi Incinerator 100kg/jam Spesifikasi dan Daftar Material Dimensi dan Power Capacity Nama Barang                                : INCINERATOR Type / Model                 : PWR-INC-KMN 10 Kapasitas                                 : 100kg/Jam (1 m3) Length                               : 288 cm   Width                                : 147 cm   Height                                    : 163 cm   Height of Chimney std            : 700 cm   TOTAL WEIGHT                   : 8000 kg  Panel – timer                 : Digital Included Auto Alarm Finishing                            : Hot endured paint  Fuel tank                           : 200 Liter  Covering Element from steel   : 3-8mm  Banyaknya Burner                   : 2 pcs   Banyaknya Blower               : 2 pcs  Max. Fuel consumption           : 15-30 Liter/Jam …

Continue ReadingSupply of Inclinators for Interim Arrival Domestic Terminal Project

Supply of Inclinators for Interim Arrival Domestic Terminal Project

CMC Services for Inclinators for 3 years including all spares, consumables, Skilled Manpower, tools and tackles all complete. As per Scope attached as Annexure Design, Manufacture, Supply, delivery to site, installation, testing & commission of All weather proof Passenger Inclinators in accordance to the Scope and outline specifications mentioned in AnnexureSpesifikasi Incinerator 100kg/jam Spesifikasi dan Daftar Material Dimensi dan Power Capacity Nama Barang                                : INCINERATOR Type / Model                 : PWR-INC-KMN 10 Kapasitas                                 : 100kg/Jam (1 m3) Length                               : 288 cm   Width                                : 147 cm   Height                                    : 163 cm   Height of Chimney std            : 700 cm   TOTAL WEIGHT                   : 8000 kg  Panel – timer                 : Digital Included Auto Alarm Finishing                            : Hot endured paint  Fuel tank                           : 200 Liter  Covering Element from steel   : 3-8mm  Banyaknya Burner                   : 2 pcs   Banyaknya Blower               : 2 pcs  Max. Fuel consumption           : 15-30 Liter/Jam …

Continue ReadingSupply of Inclinators for Interim Arrival Domestic Terminal Project

Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS

Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS Medical Waste Incinerator, 100 to 120 Kg/hr Application   For incineration, general and pathological Capacity    100 C 120 kg/h burn rate Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                Minimum 8 hours daily Operating temperature     From 850 0C to 1200 0C, Automatic controlled Residual Ash                    5 to 10% Construction Constructed from heavy duty mild or aluminized  steel Or equal and approved equivalent Insulation material            Refractory material lining similar or equal to calcium  Silicate and hot face combination of heavy duty brickwork Internal Construction        Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door                   Suitable for manual loading of wastes and with smooth  Dear seal equivalent of Ceramic seals with hinges. Door Lock                          Automatic, Electric type Ash removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamber Gratings   …

Continue ReadingSupply, Installation and Commissioning of DIESEL FIRED INCINERATORS

Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS

Supply, Installation and Commissioning of DIESEL FIRED INCINERATORS Medical Waste Incinerator, 100 to 120 Kg/hr Application   For incineration, general and pathological Capacity    100 C 120 kg/h burn rate Type Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit Operating time                Minimum 8 hours daily Operating temperature     From 850 0C to 1200 0C, Automatic controlled Residual Ash                    5 to 10% Construction Constructed from heavy duty mild or aluminized  steel Or equal and approved equivalent Insulation material            Refractory material lining similar or equal to calcium  Silicate and hot face combination of heavy duty brickwork Internal Construction        Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material Charging Door                   Suitable for manual loading of wastes and with smooth  Dear seal equivalent of Ceramic seals with hinges. Door Lock                          Automatic, Electric type Ash removal door    Provided, for removing resultant bottom ash leftovers                              from the Primary chamber Gratings   …

Continue ReadingSupply, Installation and Commissioning of DIESEL FIRED INCINERATORS

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day

hot medical waste disposing machine, Operation Condition: 8-16 hr/ day  Control: Built-in data recording Operating temperature: Incinerator  /Primary Combustion Chamber Primary Chamber: 900 – 1200 0C Type: continuous loading, Top Loading Capacity/Burn rate per hour: 250 -300 kg/hr  Material: External- 3 layers  Internal lining:  a fire proof material of pre-fired refractory bricks with Aluminium lining, resistant to corrosive waste or gas and to thermal shock Secondary  Combustion  Chamber: Type: horizontal/vertical Temperature:  1200- 1300 oC Residence time of gases : >2 seconds Ash Residue: <5% of original waste size Ash Handling System: Both Automatic and manual removal of Ash. Must ensure removal/treatment of hazardous remnants of ash Flue gas treatment   system : Capable of treating the flow of flue  gas as the incinerator is operating at its maximum capacity Auxiliary device: Water level gauge, pressure sensor, PH sensor..etc  Auxiliary device: Fuel cut-off device Waste  feeding mechanism: Automatic pneumatic/hydraulic waste loading system or conveyor belt , capacity 650-800 L at a time                                                                                                                                       Chimney (Stack): Type: Vertical type height:>7 meter’ Material: Fireproof cast, stainless steel OUTPUT:  GAS- SMOKELESS,ODORLESS  ASH -Max <5% of original waste size Reduction of Pollutant gas SO2, HCL, HF and line particulate…

Continue Readinghot medical waste disposing machine, Operation Condition: 8-16 hr/ day