HICLOVER TS100 Top-Loading Incinerator C High-Efficiency Waste Disposal Solution
The HICLOVER TS100 top-loading incinerator is a robust and efficient waste treatment system engineered for hospitals, laboratories, industrial facilities, and community waste centers. Designed with advanced combustion technology, it provides a clean, safe, and environmentally friendly method of disposing of medical, general, and animal waste.
1. Overview of the HICLOVER TS100 Incinerator
The TS100 model features a top-loading design that simplifies waste charging and maximizes chamber capacity. Its heavy-duty structure, refractory-lined chambers, and PLC-based combustion control make it one of the most durable and reliable incinerators in its class.
Key features:
-
Top-loading system: Allows easy loading of waste materials directly from above, reducing handling risks and improving operator safety.
-
Dual-chamber combustion: Ensures complete waste destruction with high temperature in the primary chamber (850C1100°C) and clean gas re-burning in the secondary chamber (>1100°C).
-
Automatic control: Optional PLC control panel with temperature sensors and timers ensures stable operation and minimal operator intervention.
-
Fuel flexibility: Compatible with diesel, natural gas, or LPG burners for global deployment versatility.
-
Compact, reinforced structure: The incinerator body is built with high-strength steel and refractory lining for long service life and high thermal efficiency.
2. Technical Performance
| Parameter | Specification |
|---|---|
| Model | TS100 |
| Feed Capacity | 100C120 kg/hour |
| Chamber Volume | Primary: 1.2 m3 / Secondary: 0.6 m3 |
| Loading Mode | Top-loading |
| Combustion Temperature | 850C1100°C |
| Fuel Type | Diesel / LPG / Natural Gas |
| Control System | Manual or PLC automatic |
| Construction | Refractory-lined steel chamber |
| Optional System | Wet scrubber or dry filtration system |
The TS100 incinerator achieves 99.9% combustion efficiency, ensuring minimal ash residue and compliance with international emission standards such as EU IED, WHO, and GB18484-2020.
3. Advantages of the Top-Loading Design
The top-loading chamber offers key operational benefits:
-
Simplified waste handling―operators can load waste directly using bins or lifting devices.
-
Improved safety―no side-door exposure during operation.
-
Optimized internal airflow―vertical layout ensures consistent flame distribution and complete combustion.
-
Compact footprint―ideal for containerized or trailer-mounted installation.
4. Applications
The TS100 model is widely adopted by medical institutions, relief organizations, military camps, and industrial complexes for safe on-site waste disposal. Typical uses include:
-
Medical waste treatment (infectious materials, sharps, PPE, etc.)
-
Animal carcass disposal in veterinary clinics and farms
-
Municipal waste management in remote or high-density areas
-
Industrial solid waste reduction
5. Environmental and Safety Compliance
The TS100 system integrates optional wet scrubber, quench tower, or baghouse filter modules for effective flue gas purification. These systems remove particulates, acid gases, and odors, ensuring that emissions meet international air quality standards.
In addition, the double-chamber and high-temperature design guarantees that dioxins and harmful gases are fully decomposed before exhaust discharge.
6. Global Projects and Deployment
HICLOVER incinerators are deployed in over 40 countries, including Kenya, Afghanistan, Tanzania, Oman, and Papua New Guinea, and are widely recognized by organizations such as the UNDP, WHO, and World Bank. The TS100 model, in particular, is often selected for healthcare and emergency waste treatment projects due to its durability and simple operation.
7. Why Choose HICLOVER
-
Over 20 years of manufacturing expertise
-
Proven reliability in extreme environments
-
Flexible design options (stationary, skid-mounted, or containerized)
-
Global after-sales support and spare parts availability
8. Contact Information
For technical details, quotations, and customization requests, contact:
HICLOVER C Waste Incinerator Manufacturer
Website: www.hiclover.com
Email: [email protected]
2025-11-17/10:31:53
|
Incinerator Items/Model |
HICLOVER TS100(PLC)
|
|
Burn Rate (Average) |
100kg/hour |
|
Feed Capacity(Average) |
150kg/feeding |
|
Control Mode |
PLC Automatic |
|
Intelligent Sensor |
Continuously Feeding with Worker Protection |
|
High Temperature Retention(HTR) |
Yes (Adjustable) |
|
Intelligent Save Fuel Function |
Yes |
|
Primary Combustion Chamber |
1200Liters(1.2m3) |
|
Internal Dimensions |
120x100x100cm |
|
Secondary Chamber |
600L |
|
Smoke Filter Chamber |
Yes |
|
Feed Mode |
Manual |
|
Burner Type |
Italy Brand |
|
Temperature Monitor |
Yes |
|
Temperature Thermometer |
Corundum Probe Tube, 1400℃Rate. |
|
Temperature Protection |
Yes |
|
Automatic Cooling |
Yes |
|
Automatic False Alarm |
Yes |
|
Automatic Protection Operator(APO) |
Yes |
|
Time Setting |
Yes |
|
Progress Display Bar |
3.7 in” LCD Screen |
|
Oil Tank |
200L |
|
Chimney Type |
Stainless Steel 304 |
|
1st. Chamber Temperature |
800℃–1000℃ |
|
2nd. Chamber Temperature |
1000℃-1300℃ |
|
Residency Time |
2.0 Sec. |
|
Gross Weight |
7000kg |
|
External Dimensions |
270x170x190cm(Incinerator Main Body) |
|
Burner operation |
Automatic On/Off |
|
Dry Scrubber |
Optional |
|
Wet Scrubber |
Optional |
|
Top Loading Door |
Optional |
|
Asbestos Mercury Material |
None |
|
Heat Heart Technology(HHT) |
Optional |
|
Dual Fuel Type(Oil&Gas) |
Optional |
|
Dual Control Mode(Manual/Automatic) |
Optional |
|
Temperature Record |
Optional |
|
Enhanced Temperature Thermometer |
Optional |
|
Incinerator Operator PPE Kits |
Optional |
|
Backup Spare Parts Kits |
Optional |
|
Mobile Type |
Optional:Containerized/Trailer/Sledge Optional |