medical waste PYROLYTIC INCINERATOR
Parameter Compliance Type of Waste To treat medical waste, categories A,B,C,D,E Type of Incinerator Pyrolytic Nominal Burn rate 50 t0 60 kg/ hr at 3500Kcal/Kg Loading Manual, Batch Load De…
Parameter Compliance Type of Waste To treat medical waste, categories A,B,C,D,E Type of Incinerator Pyrolytic Nominal Burn rate 50 t0 60 kg/ hr at 3500Kcal/Kg Loading Manual, Batch Load De…
Pig corpses / stray dogs and larger animal carcasses – Load capacity in the range of up to 300 kg / Burn rate approx. 50 kg per hour Temperature Controlled Burner. Incinerators to be designed to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, reliable, economical Incinerator with relevant control, easy to operate and self-contained. Units to be pre-assembled, pre-piped, pre-wired & tested before Transport / Export The supply will comprise the special equipment for effective medical / clinical waste management as mentioned above for a new private environment management company with operations in West and East Malaysia; Indonesia and Thailand to carry out those professional services in order to comply with the safe disposal requirements for clinical and medical waste in the region and to meet the higher technical standard in this particular field. 1.Burning rate: 250 Kg/hr. 2.It should be able to Operate not Less than 10 hours/day 3.This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… 4.Design Specification: Types A, B, C, D, and E of medical waste 5.“PYROLYTIC” combustion, by controlling the gasification of waste. 6.The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings. 7.It should be able to reduce the volume of wastes by 98%. 8.It should be able to hold emission in the second burn with gas residence of not less than 2 seconds. The incineration should be completely free from visible smoke as well as offensive odours. 9. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg The Temperatures of combustion: Minimum will be 850oC and max 1400oC Post combustion: >1100oC. 10. The Internal diameter of the Chimney: Ø 400mm² and its height: 8 Meter 11. The Volume of the combustion chamber: Not Less Than 2.3 M³ 12. Burner operation should be Automatic On/Off 13. Fuel : diesel, LPG, Natural Gas, Bio fuel 14. The supplier must provide necessary information for the best of the installation
Double Combustion Chamber Containerized Mobile Incinerator All waste burner design with dual burning chamber. Heat, Smoke Remedy , No black smoke, Environment-friendly. Family Pet Dog&Cat Cremation The burner mounted in…
[China] Solid Waste Environmental online waste incineration fields growth momentum is difficult, as well as also the brightest of resources going after also appear various times in the in 2014…
If burning and also incineration is utilized, the gadgets selected requirement to be made as well as sized to match the waste produced, lessen fire danger as well as likewise…
Waste type organics domestical waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length Width Height Extra width for burners…
MEDIUM-CAPACITY ANIMAL CARCASS INCINERATOR HICLOVER Model TS100(PLC) with wet scrubber optional Items/Model TS100( PLC) Photo Principle Waste Incineration Treatment( Fowl as well as dead fish Chamber Volume 0.97 m3 ––…
Nanjing Clover Medical Modern Technology Co., Ltd. is a leading waste burner manufacturer in China. We're local supplier and also among the largest merchant of China.The manufacturing center workshop neighborhood…
Waste type organics domestical waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length Width Height Extra width for burners…
Nanjing Clover Medical Innovation Co., Ltd. is a leading waste incinerator manufacturer in China. We're local manufacturer and one of the largest merchant of China. Pyrolytic burner apparatus technological is…